Urea Formaldehyde Foam Insulation (UFFI) Technical Data Sheet No. 96-7 (Has the appearance and consistency of white shaving cream foam when pumped into the cells or cavities of masonry walls)
C11011 1903225 K 0-01-02-030433 RATUIJAZ-RUEVDFH0036 2251845-UUUU--RUGSGOF RHHMGSC On April 2, 1982 the Consumer Safety Products Commission published a ban on urea-formaldehyde foam insulation in the Federal Register, which became effective on August 10, 1982. In conformance with this requirement, the department intends to notify the public by publication in the Federal Register of withdrawal of use of materials (um) Bulletin no. 74 Thermal Insulation, urea based foamed in place as a HUD publication and removal of um no. 74 from all volumes of the minimum property standards where it is incorporated by reference. Donald K. Baxter ORNL-Sub-78-86993/1 Performance Characteristics of Foamed-In-Place Urea Formaldehyde InsulationR.P. Tye and A.O. Desjarlais
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Reduction in Dimensions | Reduction of Effective Thermal Resistance,b % | |
|---|---|---|
| (%) | Initial R-14.7c | Initial R-18.55 |
| 1 | 6.7 | 8.4 |
| 2 | 12.8 | 15.4 |
| 3 | 18.0 | 21.8 |
| 4 | 22.9 | 27.2 |
| 5 | 27.2 | 31.8 |
| 7 | 34.5 | 39.9 |
a Calculated according
to National Bureau of Standards model.
Source: W. J. Rossiter, Jr., R. G. Mathey, D.M. Burch, and E. J. Pierce, "Urea
Formaldehyde Based Foam Insulations: An Assessment of Their Properties and Performance,"
NBS Tech. Note (U.S.) 946, National Bureau of Standards, Washington, July 1977.
b As a function of thermal resistance of cavity fill (Rwall = 2.6).
c Equivalent to typical urea formaldehyde insulation.
For more information, see Technical Data Sheet 96-7
The dimensional and mechanical properties of a urea formaldehyde product subjected to different temperature and humidity conditions for periods up to 8 months were measured. The thermal performance of a typical wall cavity containing thermal insulation and representing different sizes and positions of vertical air gaps were also measured. The air gap sizes were varied to cover a range equivalent to a 7% total reduction in cavity insulation dimensions. Various analytical techniques for the calculation of thermal performance were compared.
The conditioning study indicated that the installed 28-d urea formaldehyde density varied up to 25%. It had average linear shrinkage of 3.3% after curing and continued to shrink with time. After 8 months it had an average linear shrinkage of 5.4%. For all combinations of temperature and relative humidity the material showed reduced compressive strength with time. For high-temperature, high-humidity conditions the material had virtually no strength after 1 month. It had disintegrated after 8 months. Vapor appeared to influence the mechanical and dimensional properties more significantly than temperature alone.
The air gap study indicated a linear relationship between reduction in thermal performance and air gap size for reductions up to 7% in the linear dimensions of the insulation. The analysis of the results indicated that the parallel model can be used to derive representative thermal performance for cavity walls containing air gaps. The study did not include air gaps in the insulation of air infiltration effects. Thus the results provided minimum reductions when considering real life performance of insulated cavity walls.
Recommendations for further work to complement this study include the following:
Report Number CBL-2b
Work Performed Under Purchase Order Number: 119
Submitted By: Timothy J. Kunz
Project Manager
Testing Services Division
As indicated in the results tables, the samples exhibited some of the characteristics of previously available products. The dimensional stability tables show 9 of 14 samples had significant cracking after 13 days and 3 or 8 samples were broken and not measurable after 34 days. All of the samples were difficult to handle and easily compressed with finger pressure.
Linear shrinkage as a result of curing was calculated for one material by measuring the difference in the block cavity dimensions and those of the foam that was removed. This was measured in each of the two "Cossitt from block" cavities. This was found to be 5.2% in average dimension (15.6% volume). This compares well with previously measured values of 3-6% average per dimension. The following dimensional changes due to conditioning are in addition to the initial changes do to cure.
Linear shrinkage due to conditioning was calculated at approximately 1 week intervals. For the samples exposed full-time, average dimensional changes to date peaked in 2 weeks at +0.8% and was dropping to -0.6% in 5 weeks. Because the "Cossitt in block" samples are conditioning at 2 weeks behind the others, and 2 of the other 8 samples were not measurable at 5 weeks, the average values represent 11 samples at 1 week and 6 samples at 5 weeks. Limited data is available for dimensional stabilities over this short period of time. A study conducted for ORNL indicates a dimensional change of -0.9% after 4 weeks at the same condition.
The three samples being cycled showed dimensional changes of +1.0% wet at week 1, -3.1% dry at week 2, -0.2% wet at week 3, -3.5% dry at week 4 and -2.3% west at week 5. The cycling study previously described was conducted at generally more humid conditions (~70*F/95% RH_50% RH) for longer cycle periods. The dimensional changes corresponding to the same period of time were -3.2% after the last dry condition and -0.6 after the last wet. At the first dry observation the density recovered to about 3% less than the received density. The shrinkage in volume was somewhat equal to the loss in mass.
One significant difference in the results is the mass increase that occurred. An increase has not been found in any of the previous studies of exposures to high humidities at this early stage of conditioning. Ignoring outliers, average mass increases of 76%, 112% and 26% for each specimen type was measured at the ...
TEK 6-2A
Energy & IAQ (1996)
Keywords: insulation, reinforced concrete masonry, R-values, thermal insulation, thermal properties
Introduction
Concrete masonry walls are often constructed of hollow units with cores filled
with loose fill material and/or grout. This construction method provides the
minimum wall thickness, while allowing insulation and reinforcement to be included
to increase thermal and structural performance, respectively.
Determining the thermal insulation values of these walls, however, can be time consuming, especially when the wall is composed of several materials. This TEK facilitates the determination of thermal resistance (R) and thermal transmittance (U) of these single wythe concrete masonry walls.
R-Value Tables
Tables of calculated R-values for hollow block of 6, 8, 10 and 12 in. (152,
203, 254, and 305 mm) thicknesses, for concrete densities of 85 to 135 lb/ft3
(1362 to 2163 kg/m3) are included. In addition, Table 1 shows the approximate
percentage of grouted and ungrouted wall area for different vertical and horizontal
grout spacings, which can be used to determine R-values of partially grouted
walls. Thermal properties used in compiling the tables are listed in Table 6.
Table 1 - Percent Ungrouted Area/Percent Grouted Area For Partially Grouted Walls
| Vertical grout spacing in. (mm) | |||||||
|---|---|---|---|---|---|---|---|
| No Vert. Grout |
48 (1219) |
40 (1016) |
32 (813) |
24 (610) |
16 (406) |
||
| Horizontal grout spacing, in. (mm) |
No Horiz. Grout | 100 / 0 | 83 / 17 | 80 / 20 | 75 / 25 | 67 / 33 | 50 / 50 |
| 48 (1219) | 83 / 17 | 69 / 31 | 67 / 33 | 63 / 37 | 56 / 44 | 42 / 58 | |
| 40 (1016) | 80 / 20 | 67 / 33 | 64 / 36 | 60 / 40 | 53 / 47 | 40 / 60 | |
| 32 (813) | 75 / 25 | 63 / 37 | 60 / 40 | 56 / 44 | 50 / 50 | 37 / 63 | |
| 24 (610) | 67 / 33 | 56 / 44 | 53 / 47 | 50 / 50 | 44 / 56 | 33 / 67 | |
| 16 (406) | 50 / 50 | 42 / 58 | 40 / 60 | 37 / 63 | 33 / 67 | 25 / 75 | |
In addition to the core insulations listed in Tables 2 through 5, polystyrene inserts are available which fit in the cores of concrete masonry units. Inserts are available in many shapes and sizes to provide a range of insulating values and accommodate various construction conditions. Specially designed concrete masonry units may incorporate reduced-height webs to accommodate inserts. Such webs also reduce thermal bridging through masonry, since the reduced web area provides a smaller cross-sectional area for heat flow through the wall. To further reduce thermal bridging, some manufacturers have developed units with two cross webs rather than three. In addition, some inserts have building code approval to be left in the grouted cores, thus improving the thermal performance of fully or partially grouted masonry walls.
The ASHRAE series-parallel method (also called isothermal planes) (ref. 1) was used to calculate the base case values (i.e., the row Exposed block, both sides) in Tables 2 through 5. This method accounts for the thermal bridging through the webs of concrete masonry units. R-values of the various finish systems are added to these base values. To determine R-values for walls with 2 in. (51 mm) of rigid insulation (expanded polystyrene, extruded polystyrene, or polyisocyanurate) rather than the 1 in. (25 mm) shown in the tables, simply add the appropriate insulation thermal resistivity value from Table 6 to the R-values in Tables 2 through 5.
R-values of concrete masonry walls are correlated to concrete density, since thermal conductivity of concrete increases with increasing density. Tables 2 through 5 list a range of R-values for each density, as well as a single value, which represents a calculated middle of the range. The U-factor is determined by simply inverting the R-value (i.e., U=1/R).
A range of thermal values is appropriate for concrete products because the thermal conductivity of concrete cannot always be accurately estimated from density alone. The thermal conductivity of concrete varies with aggregate type(s) used in the concrete mix, the mix design, moisture content, etc.
These published values reflect a compendium of historical data on thermal conductivity of concrete (refs. 1,3). Locally available products and local conditions may result in thermal values which fall outside of this range. The middle-of-the-range values are presented for use in cases where more accurate values are not available from local manufacturers.